🔬 Laboratory · 7 min

Caring for lab equipment

Good equipment care costs minutes. A breakdown, or a wrong result you did not notice, costs days. Make care a routine, and write it down.

The bench basics

  • Microscope: Handle it with two hands. Clean lenses only with lens paper. After using oil, wipe the oil objective clean. Turn the light down, switch off, put the lowest-power objective in position and cover it. Keep it dry to avoid fungus on the lenses.
  • Centrifuge: Always balance it. Tubes of equal weight and volume go opposite each other. Use a balance tube with water if you have an odd number. Close the lid, start, and never open it until the rotor has stopped fully. Never run a centrifuge with one tube. Check for cracks, spills and broken tubes in the buckets.
  • Pipettes: Check for damage, use the right tip, hold the pipette upright, and never lay it flat with liquid inside. Do not use it outside its volume range. Have pipettes checked or calibrated on the schedule in your SOP, even if they "feel fine".

Analysers and logs

Follow the maker's daily, weekly and monthly maintenance. Keep a maintenance log for every machine: date, what was done, who did it. Record calibrations and control results too. Keep a cleaning schedule on the wall and tick it off after each task. Switch machines on and off in the way the manual describes, and protect them from dust, heat and power surges.

When to call the service engineer

  • A strange noise, smell, vibration or error message you cannot clear with the manual.
  • Controls keep failing after you have checked reagents and technique.
  • Damage to the rotor, a lens, a pump or a display.
  • Any repair that needs opening the machine. Do not do that yourself.

Put an "out of order" label on the machine and report it. Log the repair and run controls before using it again.

Tip: A centrifuge with one tube is not a centrifuge. It is a very expensive way of shaking the bench.